Onze website maakt gebruik van cookies om uw ervaring te verbeteren en gebruiksstatistieken vast te leggen. Door onze site te gebruiken, stemt u in met cookies zoals beschreven in ons privacybeleid. Wij nemen uw privacy en gegevensbeveiliging zeer serieus en alle verzamelde informatie zal strikt vertrouwelijk worden behandeld.

Alles afwijzen Accepteer alles

In the electrical safety of modern homes and commercial spaces, leakage current, overload, and short circuits are the three major threats. In the past, we needed to install a Residual Current Device (RCD) and a Miniature Circuit Breaker (MCB) separately to address these risks. But now, there is a device that combines the functions of both into one, making it the “Swiss Army Knife” of electrical safety — that is the RCBO.

What is an RCBO?

Een RCBO (Residual Current Circuit Breaker with Overcurrent Protection) combines both leakage protection (RCD function) and overload/short-circuit protection (MCB function) in one compact device.
For project contractors and panel builders, this means fewer components, simplified wiring, and reduced installation time, while ensuring compliance with IEC/EN protection standards.

Residual Current Protection (RCD function):
Is designed to monitor the circuit for leakage current. If a hazardous leakage (typically 30mA or above) is detected, the device interrupts the circuit within 0.04 seconds to prevent an electric shock hazard.

Overcurrent Protection (MCB function):
This component is designed to protect against excessive current. It will trip automatically in the event of an overload (simultaneous operation of multiple high-power devices) or a short circuit (direct contact of live and neutral conductors) to mitigate the risk of fire caused by overheated wiring.

RCBO (Residual Current Circuit Breaker with Overcurrent Protection)

How Does an RCBO Work?

Residual Current Protection (RCD):
The core component for leakage protection is a current transformer, which constantly measures the current difference between the live and neutral conductors. During normal operation, the currents are equal and opposite, canceling each other out (a net zero sum). A leakage fault, such as current flowing through a person to the ground, creates an imbalance. This resulting differential current, known as residual current, is monitored. If it exceeds the predefined safety level (commonly 30mA), the RCBO’s trip mechanism is activated instantly to break the circuit.

Overcurrent Protection (MCB):
Its internal mechanism consists of two components: an electromagnetic trip for sudden, high short-circuit currents, and a thermal trip (a bimetal strip) for prolonged overloads. Depending on the type of overcurrent fault, the corresponding trip unit will be triggered to disconnect the circuit.

Why is an RCBO Superior to the Traditional Solution?

Protection Configuration Voordelen Disadvantages
Traditional Configuration: One Main RCD with Multiple MCBs Relatively low cost. Nuisance Tripping: A ground fault on any individual branch circuit will trip the main RCD, causing a whole-house power outage and complicating fault identification.
Modern Configuration: Individual RCBOs on each circuit. Enhanced Safety & Reliability: A fault in one circuit only trips its dedicated RCBO, ensuring uninterrupted power in all other circuits.

Simplified Diagnostics: The tripped RCBO immediately identifies the faulty circuit, speeding up troubleshooting. Comprehensive Protection: Offers integrated protection against electric shock, fire hazards, and equipment damage.

Higher initial cost.

Application Scenarios of RCBOs

RCBOs are especially well-suited for applications demanding a high level of safety and power continuity.

  • Residential Homes: In particular, circuits located in damp environments, including kitchens, bathrooms, outdoor outlets, and those in children’s bedrooms.
  • Commercial Premises: Such as offices, retail stores, and data centers, to ensure critical equipment does not lose power from a single circuit fault.
  • Industrial Environments: To protect individual machines and prevent downtime across the entire production line.
  • Retrofitting Old Circuits: Upgrading circuits with only overcurrent protection to provide complete electrical safety.

RCBO Selection and Installation

  1. Nominale stroom (in): Based on the circuit load (e.g., 16A, 20A, 25A) and must be matched to the current-carrying capacity of the wire.
  2. Leakage Operating Current (IΔn):
    • 30mA: Protection against direct contact (electric shock); the standard for households and general-use areas.
    • 100mA, 300mA: Protection against indirect contact (fire prevention); typically applied at the main switch or for specific equipment.
  3. Aantal Polen: A 2-pole (1P+N) RCBO shall be used for single-phase circuits.
  4. Tripping Characteristic:
    • Type B: Used in residential lighting, socket outlets, and other primarily resistive loads.
    • Type C: Designed for inductive loads (e.g., air conditioners, motors) capable of handling higher inrush currents.
  5. Brand and Standards: Choose well-known brand products that comply with national electrical standards to ensure quality and safety.

Important Note: RCBOs must be installed and wired by a qualified, licensed electrician. Faulty installation can compromise the protection, potentially resulting in serious injury or fire.

Conclusie

While it may appear to be a simple component, the RCBO is a cornerstone of modern electrical safety systems. Its intelligent, integrated design offers a level of comprehensive protection previously unattainable. An investment in electrical safety is paramount. For the well-being of your household, we strongly recommend fitting reliable RCBOs on critical circuits—or throughout your entire property—during your next renovation.

If you are sourcing RCBOs for residential, commercial, or industrial distribution panels, NUOMAK provides IEC-certified RCBO solutions with stable lead time, flexible OEM services, and competitive export pricing.
Contact our team for datasheets, model recommendations, and a fast quotation.

#!trpst#trp-gettext data-trpgettextoriginal=89#!trpen#Serafiniet versneller#!trpst#/trp-gettext#!trpen##!trpst#trp-gettext data-trpgettextoriginal=90#!trpen#Optimized by #!trpst#trp-gettext data-trpgettextoriginal=89#!trpen#Serafiniet versneller#!trpst#/trp-gettext#!trpen##!trpst#/trp-gettext#!trpen#