When you’re choosing an MCCB for your electrical system, you may come across the term LSIG protection. Understanding LSIG functions helps you ensure your system has complete and precise circuit protection. In this article, you’ll learn what LSIG means, how it works, and why it’s essential for industrial safety.
LSIG stands for Long-time, Short-time, Instantaneous, and Ground fault protection.
These four functions define how an MCCB responds to different fault conditions in an electrical circuit. An MCCB equipped with LSIG protection can detect overloads, short circuits, and ground faults, ensuring your system operates safely and reliably.
Each part of LSIG serves a unique role in protecting your equipment and minimizing downtime.
The Long-time (L) function protects your electrical system against continuous overloads that occur when current exceeds its normal value for an extended period.
It allows short-duration surges but trips the breaker if the overload persists. This prevents overheating and damage to cables, motors, or transformers.
Short-time (S) protection is designed for short-circuit faults that last only briefly.
This function introduces a small delay before tripping, allowing coordination with downstream devices. It’s especially useful in multi-level protection systems where you don’t want an upstream breaker to trip unnecessarily.
Instantaneous (I) protection provides immediate response when a large fault current occurs, such as a direct short circuit.
It trips the breaker instantly without delay to isolate the fault and prevent serious damage to the electrical installation. This function is critical in maintaining both equipment and operator safety.
Ground Fault (G) protection detects leakage currents flowing to the ground, often caused by insulation failure or damaged wiring.
This feature helps prevent electric shock, reduces fire risk, and protects sensitive equipment. In facilities where personnel safety and equipment uptime are priorities, ground fault protection is essential.
LSIG protection gives you comprehensive, layered protection for electrical systems of all sizes.
Here’s why it’s so important:
By understanding how each LSIG function operates, you can select MCCBs that provide optimal safety for your facility.
Proper LSIG settings ensure the MCCB reacts accurately to different fault levels. Follow these basic steps:
At NUOMAK, we design MCCBs with advanced electronic trip units that feature LSIG protection for total system safety.
Our breakers are engineered for industrial and commercial environments, offering:
Whether you’re managing a factory, data center, or energy system, NUOMAK MCCBs ensure your equipment stays protected and your operations run smoothly.
Understanding LSIG protection in MCCBs helps you make better, safer purchasing decisions. Each function—L, S, I, and G—plays a vital role in protecting your electrical system from overloads, short circuits, and ground faults. For MCCBs that combine intelligence, precision, and durability, NUOMAK delivers performance you can trust.
What does LSIG mean in MCCB?
LSIG stands for Long-time, Short-time, Instantaneous, and Ground fault protection, representing four key protection functions in MCCBs.
What is the function of LSIG protection?
It provides comprehensive circuit protection against overloads, short circuits, and ground faults, ensuring safety and equipment reliability.
Is LSIG available in all MCCBs?
No. LSIG protection is typically available in advanced or electronic-type MCCBs used for industrial applications.
How do I set LSIG protection properly?
Adjust the L, S, I, and G parameters based on your load type, fault level, and system coordination. Always follow the manufacturer’s instructions.
Does NUOMAK provide MCCBs with LSIG protection?
Yes. NUOMAK offers MCCBs equipped with smart LSIG trip units that meet international safety standards for industrial and commercial systems.
Privacy Policy | SiteMap
Copyright NUOMAK